- Underground Devices
- Duct Spacers
- Bore Spacers
- Nonmetallic Cable Racks
- Underground Transmission
- 8W20-2 Spacer
- 8W20-3 Spacer
- 2882W34-2 Spacer
- 28482W34-3 Spacer
- 284882W34-4 Spacer
- 2882W6434-2 Spacer
- 288282W6434-3 Spacer
- 2882W6434-2 and 2882W64-2i Spacers
- 288282W6434-3 and 288282W64-3i Spacers
- 2882W9434-2, 8W94-2i and 848W94-2i Spacers
- 282882W9434-3, 8W94-3i and 84848W94-3i Spacers
- 28288282W9434-4, 8W94-4i and 848848W94-4i Spacers
- 8W71-2 Spacer
- Technical Info
- Contact Us
Duct Donut Spacer
With the Duct Donut Spacer you can save time and effort. Your duct bank can be easily pre-assembled outside of the trench. You can also attain either 1½" or 3" separation with the same spacer.
- One style does it all
- Save up to 40% on labor
- Up to one third less spacers required on many jobs -- don't over-order
- Do more work outside the ditch instead of down inside
- Just slide them on and you have proper duct spacing in every direction -- and from sides and bottom of trench
- Cannot fall or tip over
- Place them anywhere along the run -- they don't have to be stacked -- this eliminates danger of shear plane in meeting seismic specifications
- Easy flow of concrete thru spacers in the pour
- Fits all types of conduit. Sizes for conduits 2, 3, 4, 5, 6 inches
- Snap out feature allows conversion from 3" separation to 1 1/2" separation.
| SPECIFICATIONS & ORDERING INFORMATION | |||||
|---|---|---|---|---|---|
|
|
Part No. | Duct Size | Inside Diameter | Outside Diameter | Spacer Width |
| 2C | 2" | 2.75" | 8.75" | 1.25" | |
| 3C | 3" | 3.625" | 9.625" | 1.25" | |
| 4C | 4" | 4.875" | 10.875" | 1.25" | |
| 5C | 5" | 6" | 12" | 1.25" | |
| 6C | 6" | 6.875" | 12.875" | 1.25" | |
Duct Arrangements for 1 1/2" to 2" Separation
The following are sample duct arrangements of 2 to 6 ducts for 1 1/2" to 2" separation. We recommend also using our non-metallic strapping to ease assembly of the duct bank outside the ditch. Hold Down Bars are also recommended.
| Arrangement of 2 Ducts | |
|---|---|
![]() |
![]() |
| Arrangement of 3 Ducts | |
![]() |
|
| Arrangement of 4 Ducts | |
![]() |
|
| Arrangement of 5 Ducts | |
![]() |
![]() |
| Arrangement of 6 Ducts | |
![]() |
![]() |
Duct Arrangements for 3" Separation
The following are sample duct arrangements of 2 to 6 ducts for 3" separation. For duct arrangements of more than 6 ducts, we recommend also using our non-metallic Donut Strapping to ease assembly of the duct bank outside the ditch. Hold Down Bars are also recommended.
| Arrangement of 2 Ducts | |
|---|---|
![]() |
![]() |
| Arrangement of 3 Ducts | |
![]() |
|
| Arrangement of 4 Ducts | |
![]() |
|
| Arrangement of 5 Ducts | |
![]() |
![]() |
| Arrangement of 6 Ducts | |
![]() |
![]() |
Use as a Spacer for Secondary Circuits
One Spacer can carry up to five ducts that are easily preassembled outside the trench.
Contact one of our sales representatives today
to inquire about a quote from Underground Devices