Duct Donut Spacer
With the
Duct Donut Spacer you can save time and effort. Your duct bank
can be easily pre-assembled outside of the trench. You can also
attain either 1½" or 3" separation with the same
spacer.
|
Duct
Donut Spacers
- One
style does it all
- Save
up to 40% on labor
- Up
to one third less spacers required on many jobs -- don't
over-order
- Do
more work outside the ditch instead of down inside
- Just
slide them on and you have proper duct spacing in every
direction -- and from sides and bottom of trench
- Cannot
fall or tip over
- Place
them anywhere along the run -- they don't have to be stacked
-- this eliminates danger of shear plane in meeting seismic
spcifications
- Easy
flow of concrete thru spacers in the pour
- Fits
all types of conduit. Sizes for conduits 2, 3, 4, 5, 6
inches
- Snap
out feature allows conversion from 3" separation to 1
1/2" separation.
|
|

 |
|
Specifications
& Ordering Information
|
 |
| Part
No. |
Duct
Size |
Inside
Diameter |
Outside
Diameter |
Width |
| 2C |
2" |
2
3/4" |
8
3/4" |
1
1/4" |
| 3C |
3" |
3
5/8" |
9
5/8" |
1
1/4" |
| 4C |
4" |
4
7/8" |
10
7/8" |
1
1/2" |
| 5C |
5" |
6" |
12" |
1
3/4" |
| 6C |
6" |
6
7/8" |
12
7/8" |
1
3/4" |
|
|
Duct
Arrangements for 1 1/2" to 2" Separation
The
following are sample duct arrangements of 2 to 6 ducts
for 1 1/2" to 2" separation. For duct arrangements of
more than 6 ducts, we recommend also using our non-metallic
Donut Strapping to ease assembly of the duct bank outside
the ditch. Hold Down Bars are also recommended. |
|
Arrangement
of 2 Ducts - 1 1/2" to 2" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
9
1/2" |
8
3/4" |
| 3C |
11
1/2" |
9
5/8" |
| 4C |
13
3/4" |
10
7/8" |
| 5C |
15
3/4" |
12" |
| 6C |
17
7/8" |
12
7/8" |
|
 |
| Part
No. |
Height |
Width |
| 2C |
8
3/4" |
12
5/8" |
| 3C |
9
5/8" |
14
1/2" |
| 4C |
10
7/8" |
17" |
| 5C |
12" |
19
1/8" |
| 6C |
12
7/8" |
21" |
|
|
Arrangement
of 3 Ducts - 1 1/2" to 2" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
9
1/2" |
12
5/8" |
| 3C |
11
1/2" |
14
1/2" |
| 4C |
13
3/4" |
17" |
| 5C |
15
3/4" |
19
1/8" |
| 6C |
17
7/8" |
21" |
|
|
Arrangement
of 4 Ducts - 1 1/2" to 2" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
9
1/2" |
12
5/8" |
| 3C |
11
1/2" |
14
1/2" |
| 4C |
13
3/4" |
17" |
| 5C |
15
3/4" |
19
1/8" |
| 6C |
17
7/8" |
21" |
|
|
Arrangement
of 5 Ducts - 1 1/2" to 2" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
16
3/4" |
12
5/8" |
| 3C |
19
1/2" |
14
1/2" |
| 4C |
23" |
17" |
| 5C |
26
1/4" |
19
1/8" |
| 6C |
29
3/8" |
21" |
|
 |
| Part
No. |
Height |
Width |
| 2C |
9
1/2" |
16
3/4" |
| 3C |
11
1/2" |
19
1/2" |
| 4C |
13
3/4" |
23" |
| 5C |
15
3/4" |
26
1/4" |
| 6C |
17
7/8" |
29
3/8" |
|
|
Arrangement
of 6 Ducts - 1 1/2" to 2" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
16
3/4" |
12
5/8" |
| 3C |
19
1/2" |
14
1/2" |
| 4C |
23" |
17" |
| 5C |
26
1/4" |
19
1/8" |
| 6C |
29
3/8" |
21" |
|
 |
| Part
No. |
Height |
Width |
| 2C |
9
1/2" |
16
3/4" |
| 3C |
11
1/2" |
19
1/2" |
| 4C |
13
3/4" |
23" |
| 5C |
15
3/4" |
26
1/4" |
| 6C |
17
7/8" |
29
3/8" |
|
|
Duct
Arrangements for 3" Separation
The
following are sample duct arrangements of 2 to 6 ducts
for 3" separation. For duct arrangements of more than
6 ducts, we recommend also using our non-metallic Donut
Strapping to ease assembly of the duct bank outside the
ditch. Hold Down Bars are also recommended. |
|
Arrangement
of 2 Ducts - 3" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
14
1/8" |
8
3/4" |
| 3C |
16" |
9
5/8" |
| 4C |
18
3/8" |
10
7/8" |
| 5C |
20
1/2" |
12" |
| 6C |
22
1/2" |
12
7/8" |
|
 |
| Part
No. |
Height |
Width |
| 2C |
8
3/4" |
14
1/8" |
| 3C |
9
5/8" |
16" |
| 4C |
10
7/8" |
18
3/8" |
| 5C |
12" |
20
1/2" |
| 6C |
12
7/8" |
22
1/2" |
|
|
Arrangement
of 3 Ducts - 3" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
10
1/4" |
14
1/8" |
| 3C |
12" |
16" |
| 4C |
14
1/8" |
18
3/8" |
| 5C |
16
1/8" |
20
1/2" |
| 6C |
18" |
22
1/2" |
|
|
Arrangement
of 4 Ducts - 3" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
14
1/8" |
14
1/8" |
| 3C |
16" |
16" |
| 4C |
18
3/8" |
18
3/8" |
| 5C |
20
1/2" |
20
1/2" |
| 6C |
22
1/2" |
22
1/2" |
|
|
Arrangement
of 5 Ducts - 3" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
10
1/4" |
19
3/4" |
| 3C |
12" |
22
3/8" |
| 4C |
14
1/8" |
26" |
| 5C |
16
1/8" |
29
1/2" |
| 6C |
18" |
32" |
|
|
| Part
No. |
Height |
Width |
| 2C |
15
1/2" |
14
1/8" |
| 3C |
18
3/8" |
16" |
| 4C |
21
1/2" |
18
3/8" |
| 5C |
24
1/2" |
20
1/2" |
| 6C |
27
3/8" |
22
1/2" |
|
|
Arrangement
of 6 Ducts - 3" Separation
|
 |
| Part
No. |
Height |
Width |
| 2C |
14
1/8" |
19
3/4" |
| 3C |
16" |
22
3/8" |
| 4C |
18
3/8" |
26" |
| 5C |
20
1/2" |
29
1/2" |
| 6C |
22
1/2" |
32" |
|
|
| Part
No. |
Height |
Width |
| 2C |
19
3/4" |
14
1/8" |
| 3C |
22
3/8" |
16" |
| 4C |
26" |
18
3/8" |
| 5C |
29
1/2" |
20
1/2" |
| 6C |
32" |
22
1/2" |
|
|
Use
as a Spacer for Secondary Circuits
One
spacer can carry up to five ducts that are easily pre-assembled
outside the trench.
|
|
 |

17
Duct Installation with 1 1/2" separation between racks
with non-metallic Donut Strapping used for ease of assembly outside
the ditch
|
Hold
Down Bars
Our
Hold Down Bars stop all floating
of conduits while pouring cement in trench, locks all ducts
and conduits in place.
Available
in 12" and 18" standard sizes, special lengths available.
Uses standard #3 rebar. |
|
 |
|